|本期目录/Table of Contents|

[1]王彦君,高祥璐,石浩淼,等.偏光3D显示器对视功能影响的研究[J].天津医科大学学报,2016,22(04):328-331.
 WANG Yan-jun,GAO Xiang-lu,SHI Hao-miao,et al.Influence?of polarized 3D displayer? on visual function[J].Journal of Tianjin Medical University,2016,22(04):328-331.
点击复制

偏光3D显示器对视功能影响的研究(PDF)
分享到:

《天津医科大学学报》[ISSN:1006-8147/CN:12-1259/R]

卷:
22卷
期数:
2016年04期
页码:
328-331
栏目:
临床医学
出版日期:
2016-07-19

文章信息/Info

Title:
Influence?of polarized 3D displayer? on visual function
文章编号:
1006-8147(2016)04-0328-04
作者:
王彦君高祥璐石浩淼张艳龙王 琦白 琰
(天津医科大学眼视光学院,天津300070)
Author(s):
WANG Yan-junGAO Xiang-luSHI Hao-miaoZHANG Yan-longWANG QiBAI Yan
( School of Optometry and Ophthalmology,Tianjin Medical University, Tianjin 300070,China)
关键词:
偏光3D显示器视功能视疲劳
Keywords:
polarized 3D displayer visual function visual fatigue
分类号:
R77
DOI:
-
文献标志码:
A
摘要:
?目的:研究不同眼位患者在观看偏光3D影像0.5 h和1 h后视功能参数的改变,并探讨参数改变与视疲劳的关系。方法:选取志愿者51名,根据近距隐斜量分为3组:正位组、外隐斜组、内隐斜组。分别测量观看3D影像前、0.5 h和1 h 的视功能参数,使用视疲劳调查问卷进行视疲劳程度统计。结果按眼位分,正位组和内隐斜组观看3D影像0.5 h和1 h 相比于观看前调节反应增大,差异有统计学意义(p=0.004、p<0.001,p<0.001、p=0.001)。内隐斜组观看0.5 h和1 h 立体视锐度值小于观看前,差异有统计学意义(p=0.02、p=0.03)。按时间分,观看0.5 h和1 h ,正位组和内隐斜组注视视差均小于外隐斜组,差异均有统计学意义(p=0.03、p<0.001,p=0.02、p=0.007)。观看1 h后,正位组和内隐斜组的注视视差斜率绝对值均小于外隐斜组,差异有统计学意义(p=0.007p=0.013)。观看0.5 h,外隐斜组视疲劳得分大于正位组和内隐斜组,差异均有统计学意义(p=0.034、p=0.015)。结论:不同眼位患者观看3D影像后,立体视锐度有所提升调节反应增大、注视视差变大及其斜率的改变影响了双眼协调运动,最终导致视疲劳。
Abstract:

Objective: To observe the change of visual function after viewing polarized 3D images for thirty minutes and an hour for patients with different phorias and explore the relationship between the visual function parameters’changes and visual fatigue. Methods: According to near phorias, 51 volunteers were divided into three groups:normal phoria, exophoria, esophoria. Visual function parameters were measured before viewing polarized 3D images, after viewing half an hour and an hour later. The degree of visual fatigue was measured based on visual fatigue questionnaire. Results: According to phorias , at 30 mins and 1h after viewing the 3D images, the changes of accommodation response showed statistically significant difference(P=0.004,P<0.001,P<0.001,P=0.001).The accommodation response of the patients with normal phoria and esophoria, increased. After half an hourand an hour(改为at 0.5h and 1h), the changes of stereoacuity showed statistically significant difference(P=0.02,P=0.03).The stereoacuity of the patients with esophoria, decreased. According to the time point, at thirty minutes and 1 hour, the changes of fixation disparity presented statistically significant difference(P=0.03,P<0.001,P=0.02,P=0.007).The fixation disparity of the patients with normal phoria and esophoria , increased. At hour, the absolute value of the slope of fixation disparity had statistically significant difference (P=0.007,P=0.013).The patients with normal phoria and esophoria was lower than those with exophoria .For the patients with exophoria ,the visual fatigue score increased at 0.5 h than normal phoria and esophoria with significant difference (p=0.034,p=0.015). Conclusion: The stereoacuity improves in different phorias after viewing 3D images.The increasing of accommodation response, fixation disparity and the slope of fixation disparity which affect binocular coordinated movement, eventually contributing to the visual fatigue.

?

参考文献/References:

[1] Lambooij M, IJsselsteijn W, Fortuin M, et al. Visual discomfort and visual fatigue of stereoscopic displays: A review[J]. J Imaging Sci Technol, 2009, 53(3):1

[2] 李小方,王琼华,李大海,等.柱透镜光栅3D显示器的视差范围与立体观看视疲劳的关系[J]. 光电子.激光, 2012,23(5):873

[3] Wook Wee S, Moon N J. Clinical evaluation of accommodation and ocular surface stability relavant to visual asthenopia with 3D displays[J]. BMC ophthalmology, 2014, 14(1): 1

[4] Chen C, Wang J, Li K, et al. Visual fatigue caused by watching 3DTV: an fMRI study[J]. Biomed Eng Online, 2015, 14(1): 1

[5] Chang Y S, Hsueh Y H, Tung K C, et al. Characteristics of visual fatigue under the effect of 3D animation[J]. Technol Health Care, 2015, 24(1): 231

[6] 崔耀珍,高祥璐,张艳龙,等.不同隐斜测量方法可重复性的比较[J].天津医科大学学报,

2012,18(1):115

[7] 李思思.辐揍与焦点调节不一致所引发的立体影像视疲劳研究[D].北京:北京邮电大学, 2012

[8] Tosha C, Borsting E, Ridder WH, et al. Accommodation response and visual discomfort[J]. Ophthalmic Physiol Opt , 2009,29(6): 625

[9] Emoto M, Niida T, Okano F. Repeated vergence adaptation causes the decline of visual functions in Watching stereoscopic television[J]. J Displ Technol, 2005, 1(2): 328

[10] Yano S, Ide S, Mitsuhashi T, et al. A study of visual fatigue and visual comfort for 3D HDTV/HDTV images[J]. Displays, 2002, 23(4): 191

[11] Wee S W, Moon N J, Lee W K, et al. Ophthalmological factors influencing visual asthenopia as a result of viewing 3D displays [J]. Br J Ophthalmol, 2012, 96(11): 1391

[12] 王光霁.双眼视觉学[M].第2版.北京:人民卫生出版社,2011:75

[13] Kim S H, Suh Y W, Yun C M, et al. 3D asthenopia in horizontal deviation[J]. Current

Eye Research, 2013,38(5): 614

[14] Kim S H, Suh Y W, Song J S, et al. Clinical research on the ophthalmic factors affecting 3D asthenopia[J]. J Pediatr Ophthalmol Strabismus, 2012,49(4):248

[15] Sheedy J E. Fixation disparity analysis of oculomotor imbalance[J]. Am J Optom Physiol Opt,1980,57(9):632

[16] 梅颖,吕帆,袁援生.注视侈开分析在双眼视觉功能异常诊断和治疗中的作用[J]. 眼视光学杂志,2004,6(1): 35

相似文献/References:

备注/Memo

备注/Memo:

作者简介 王彦君(1989-),男,硕士在读,研究方向:眼视光学理论与方法;

通信作者:高祥璐,E-mail:gaoxianglu8@126.com

?

更新日期/Last Update: 2016-07-13