|本期目录/Table of Contents|

[1]姜丹丹,汤 欣,苑晓勇,等.正常角膜前后表面散光的相关研究[J].天津医科大学学报,2018,24(04):248-352.
 JIANG Dan-dan,TANG Xin,YUAN Xiao-yong,et al.Study on anterior and posterior corneal astigmatism in normal cornea[J].Journal of Tianjin Medical University,2018,24(04):248-352.
点击复制

正常角膜前后表面散光的相关研究(PDF)
分享到:

《天津医科大学学报》[ISSN:1006-8147/CN:12-1259/R]

卷:
24卷
期数:
2018年04期
页码:
248-352
栏目:
出版日期:
2018-07-20

文章信息/Info

Title:
Study on anterior and posterior corneal astigmatism in normal cornea
作者:
姜丹丹汤 欣苑晓勇宋 慧
天津医科大学眼科临床学院,天津市眼科医院白内障科,天津 300041
Author(s):
JIANG Dan-dan TANG Xin YUAN Xiao-yong SONG Hui
College of Ophthalmology, Tianjin Medical University, Department of Cataract,Tianjin Eye Hospital,Tianjin 300041,China
关键词:
角膜后表面散光角膜总散光Pentacam眼前节分析仪全年龄正常角膜
Keywords:
posterior astigmatismtotal astigmatism Pentacam all ages of normal corneal human
分类号:
R778.1
DOI:
-
文献标志码:
摘要:
目的:探讨全年龄正常人角膜前后表面散光的分布规律及角膜后表面散光对角膜总散光的影响。方法:分析4岁以上在天津市眼科医院就诊患者及欲进行白内障手术患者 571例(989眼)的Pentacam眼前节分析仪检查结果,记录角膜前后表面散光,总结角膜前后表面散光的分布规律及相关关系并分析角膜后表面散光对角膜总散光的影响。模拟角膜曲率计散光用屈光指数1.337 5及角膜前表面曲率半径计算,总角膜散光根据角膜前、后表面散光度数和轴位进行矢量分解计算。结果:(1)角膜后表面散光度数平均值为(0.34±0.16)D;34.8%(345眼)为顺归散光,62.5%(618眼)为逆归散光,2.6%(26眼)为斜轴散光。(2)角膜后表面散光度数与前表面散光度数正相关(r=0.576,P<0.05),角膜前后表面散光轴位呈正相关关系(r=0.381,P<0.05)。(3)模拟角膜曲率计散光与角膜总散光大小分别为(1.21±0.76)D、(1.43±0.88)D,差异具有统计学意义(t=21.95,P<0.01);二者的散光轴位分别为(89.88±63.70)°、(89.29±61.53)°,差异无统计学意义(t=-1.08,P=0.28)。结论:角膜后表面散光度数很小,主要为逆规散光,其大小和轴位与角膜前表面散光均呈正相关;如果忽略角膜后表面散光,将会导致具有临床意义的角膜总散光的估计差异。
Abstract:
Objective: To investigate the distribution of anterior and posterior corneal astigmatism and the effect of posterior astigmatism(PA) on total astigmatism (TA) in all ages of normal corneal human. Methods: A rotating Scheimpflug camera (Pentacam Oculus,Germany) was used to measure 989 eyes of 571 patients in Tianjin Eye Hospital. The anterior astigmatism (AA) and PA was recorded. The distribution and correlation of AA and PA were summarized and the effects of PA on TA were analyzed. The simulated keratometry astigmatism (KA) was calculated by the anterior corneal surface measurement and the index of 1.337 5,while TA was derived by anterior and posterior surface astigmatism and axial vector decomposition calculation. Results: (1) The mean PA was (0.34±0.16)D;with-the-role (WTR), against-the-role(ATR), oblique astigmatism of the posterior corneal surface were found in 345 eyes (34.8% ), 618 eyes (62.5%) and 26 eyes(2.6%).(2) The magnitudes of AA and PA were significantly correalated (Pearson correlation coefficient r=0.576,P<0.05). The axis of AA and PA were significant positive correlation(r=0.381,P<0.05).(3) The magnitude of TA and KA were (1.21±0.76)D and (1.43±0.88)D,respectively,with significant difference(t=21.95,P<0.01). The axis of TA and KA were(89.88±63.70)° and(89.29±61.53)°, respectively, without significant difference(t=-1.08,P=0.28). Conclusion: The diopter of PA is mostly low and mainly with the axis ATR. There is significant positive correlation between the magnitude and axis of PA and AA; If PA is neglected, it will lead to clinically significant inaccuracies in estimation of the corneal astigmatism.

参考文献/References:


[1] Stavridis E, Eppig T,Szentmáry N,et al. Reproducibility of Scheimpflug tomography measurements regarding corneal front and back surface power[J]. Klin Monatsbl Augenheilkd,2015,232(11):1297
[2] Crawford A Z,Patel D V,Mcghee C N. Comparison and repeatability of keratometric and corneal power measurements obtained by orbscan II,pentacam,and galilei corneal tomography systems[J]. Am J Ophthalmol,2013,156(1):53
[3] Royston J M,Dunne M C,Barnes D. Measurement of posterior corneal surface toricity[J]. Optom Vis Sci,1990,67(10):757
[4] Miyake T,Kamiya K,Amano R,et al. Long-term clinical outcomes of toric intraocular lens implantation in cataract cases with preexisting astigmatism[J]. J Cataract Refract Surg,2014,40(10):1654
[5] Kessel L,Andresen J,Tendal B,et al. Toric intraocular lenses in the correction of astigmatism during cataract surgery:a systematic review and meta-analysis[J]. Ophthalmology,2016,123(2):275
[6] Koch D D,Jenkins R B,Weikert M P,et al. Correcting astigmatism with toric intraocular lenses: effect of posterior corneal astigmatism[J]. J Cataract Refract Surg,2013,39(12):1803
[7] Abulafia A,Hill W E,Franchina M,et al. Comparison of methods to predict residual astigmatism after intraocular lens implantation[J]. J Refrac Surg,2015,31(10):699
[8] Park D Y,Lim D H,Hwang S,et al. Comparison of astigmatism prediction error taken with the Pentacam measurements,Baylor nomogram,and Barrett formula for toric intraocular lens implantation[J]. BMC Ophthalmol,2017,17(1/9):156
[9] Koch D D,Ali S F,Weikert M P,et al.Contribution of posterior corneal astigmatism to total corneal astigmatism[J]. J Cataract Refract Surg,2012,38(12):2080
[10] Ho J D,Tsai C Y,Liou S W.Accuracy of corneal astigmatism estimation by neglecting the posterior corneal surface measurement[J].Am J Ophthalmol,2009,147(5):788
[11] Nemeth G,BertaA,Lipecz A,et al.Evaluation of posterior astigmatism measured with scheimpflug imaging[J]. Cornea,2014,33(11):1214
[12] 张蝶念,张红,田芳,等.老年性白内障患者中角膜后表面散光对总角膜散光的影响[J].眼科新进展,2015,35(7):652
[13] TonnB,Klaproth O K,KohnenT.Anterior Surface-Based keratometry compared with scheimpflug Tomography-Based total corneal astigmatism[J]. Invest Ophthalmol Vis Sci,2015,56(1):291
[14] Savini G,Naeser K.An analysis of the factors influencing the residual refractive astigmatism after cataract surgery with toric intraocular lenses[J]. Invest Ophthalmol Vis Sci,2015,56(2):827
[15] Kanellopoulos AJ,Asimellis G. Repeatability of Corneal Astigmatism Measurements.(magnitude and axis) evaluated with color light emitting diode reflection topography[J]. Cornea,2015,34(8):937
[16] 廖茉莉.白内障患者角膜后表面散光的分布研究[J].当代医学,2014,20(33):84

相似文献/References:

备注/Memo

备注/Memo:
-
更新日期/Last Update: 2018-07-20